Skip to content

0054 — The cubed sphere's default cap: 30 degrees ​

  • Status: Accepted
  • Date: 2026-10-31

Context ​

Since ADR 0052 a cubed-sphere march that folds a cell is refused. Its default cap angle, theta_cap = 0.05π (9°), folds the cap corners in every algebraic case of ADR 0052's sweep: sphere and capsule at three sizes, 4–104 folded cells. It also trips the cap/equator C1-pinning fallback warning. So shore mesh body.stl, with the defaults, now fails on most bodies.

At 30°, the same sweep has no fold and no warning: both bodies, the three sizes, both schemes, minimum scaled Jacobian 0.57 or more. ADR 0052 left the change to the owner, because the default backs ADR 0034's frozen R8 goldens. The owner chose the per-topology default with a legacy guard (option A, 2026-10-31).

Decision ​

  1. The cubed sphere's default cap is π/6 (30°). It applies in CubedSphereTopology.build, Mesh.from_stl / from_file, Project.build_topology and shore mesh.
    • The O-grid keeps 0.05π. There theta_cap is the polar opening: the O-grid covers colatitudes [θ, π − θ], so 30° would leave 30° holes.
    • topology.CUBED_SPHERE_THETA_CAP and topology.LEGACY_THETA_CAP name the two values.
    • OH still pins 45°.
  2. Journals carry the value. Project.build_topology("cubed_sphere", …) without theta_cap adds the default to its parameters, so the journal line says theta_cap=0.5235987755982988. No journal depends on a default again. shore mesh already wrote the value it used.
  3. Projects become format 4.
    • Legacy guard: while a project saved before format 4 replays, a cubed sphere built without theta_cap gets the old 0.05π (commands.legacy_theta_cap, like ADR 0026's legacy_collar_volume). Its saved grids match bit for bit, and a re-save journals 0.05π explicitly.
    • Loading without replay (ADR 0033) accepts formats 3 and 4, both of which save face graphs.
  4. Re-freezes, approved by the owner 2026-10-31.
    • ADR 0034 R8's cubed-sphere goldens are regenerated at the new default. The other topologies' entries are unchanged, checked byte for byte.
    • test_cap_folds F1, F2 and F4 give 9° explicitly.
    • test_fast_load L1 and test_collar_default D1 check format = 4.
    • The golden must change with the default. A separate re-freeze commit would fail its own gate, so the golden is in the implementation commit.

Alternatives considered ​

  • Keep 9° and document it: the default command fails on most bodies.
  • Change the default only in the CLI: the CLI and Python defaults would disagree.
  • Treat a missing theta_cap in any replayed journal as 9°: a hand-written script run through shore run would silently get 9°.

Consequences ​

  • shore mesh body.stl (cubed sphere) marches the sweep's cases cleanly, without the C1 warning.
  • Bare journal scripts written before ADR 0054 that build a cubed sphere without theta_cap replay at 30°. They carry no format, so nothing can tell them apart. Add theta_cap=0.15707963267948966 to replay the old grid. Saved projects are protected by the guard.
  • The docs no longer need --theta-cap-deg 35 to avoid folds; the tutorials keep their explicit value.

Verification ​

tests/spec/test_default_cap.py (main job), frozen before the implementation:

  • C1–C3: the Python, CLI and Mesh.from_stl defaults give the same 30° grid, fold-free, without the warning, journaled explicitly.
  • C4: the O-grid's default is unchanged (a guard).
  • C5: a format-3 project made at the base commit (data/cap9_project.zip) loads bit for bit (a guard).
  • C6: saved again, it is format 4 and journals 0.05π.
  • C7: new projects save format 4.

At freeze: 2 passed, 5 xfailed.

A mutation check confirmed the guard is live: with a 30° legacy value, C5 fails, because the replay no longer matches the saved grids.

Released under the MIT License.